Web Manager for OnSite Administrators 271
Configuration>Serial/AUX>Notifications
3. Select “Email,” “Pager,” or “SNMP trap” from the pull-down menu.
4. To create a new entry for an event to trigger an alarm or notification, click
the Add button.
5. To edit a previously-configured trigger, click the Edit button.
6. Go to one of the following procedures.
•“"To Configure a Trigger for Email Notification for Serial
Ports [Expert]
• “To Configure a Trigger for Pager Notification for Serial
Ports [Expert]” on page 272
• “To Configure a Trigger for SNMP Trap Notification for Serial
Ports Expert]” on page 272
T To Configure a Trigger for Email Notification
for Serial Ports [Expert]
1. Go to Configuration>Serial/AUX>Notifications in Expert mode, select
“Email” from the pull-down menu; optionally, configure an alarm to
sound when the trigger action occurs; and click either Add or Edit.
If needed, see “To Choose a Method for Sending Notifications for Serial
Port Data Buffering [Expert]” on page 217.
2. Specify the function you want to trigger a notification in the “Alarm
Trigger” field using the required syntax.
3. Enter the recipient for notification email in the “To” field.
Enter the username only in this field. The email is sent to
username@server, where server is the value entered in Step 7.
4. Enter an email address identifying the OnSite in the “From” field.
5. Enter the subject in the “Subject” field.
6. Enter an explanatory text message in the “Body” field.
7. Enter the SMTP server’s IP address or DNS name in the “SMTP Server”
field.
8. Enter the SMTP port number in the “SMTP Port” field.
Commenti su questo manuale